Pandemic SARS CoV-2 is currently spreading around the world. Preventive measures to be implemented include using Personal Protective Equipment (PPE) especially mask which lead to a lack of mask supply. Strategy is proposed by decontaminating it so that it can be used repeatedly. This research was conducted to compare the effectiveness of UV radiation disinfection in different duration on the KN95 mask. This research was conducted by decontaminating of KN95 mask using UV radiation with radiation time of 15, 30, and 45 minutes. The mask was swab before and after the radiation. Examination for the growth of pathogen bacterial colonies and total plate count method was done to determine the effectivity. It was found the number of germs before and after  has decreased significantly radiation at 30 (P = 0.036) and 45 minutes (P = 0.037). It also can be effective in decontaminating pathogen bacterial as the number colony of Staphylococcus aureus has decreased significantly in 30 minutes (P=0.034) and 45 minutes exposure (P= 0.037).  The results of this study indicate that UV radiation for 30 and 45 minutes can be effective in decontaminating pathogen bacterial
Keywords
uv radiation; KN95 mask; total plate count
  1. J. Whitworth, “COVID-19: a fast evolving pandemic,” Transactions of The Royal Society of Tropical Medicine and Hygiene, vol. 114, no. 4, pp. 241–248, Apr. 2020, doi: 10.1093/trstmh/traa025.
  2. N. van Doremalen et al., “Aerosol and Surface Stability of SARS-CoV-2 as Compared with SARS-CoV-1,” N Engl J Med, vol. 382, no. 16, pp. 1564–1567, Apr. 2020, doi: 10.1056/NEJMc2004973.
  3. N. Sharma, Z. Hasan, A. Velayudhan, E. M. A., D. K. Mangal, and S. D. Gupta, “Personal Protective Equipment: Challenges and Strategies to Combat COVID-19 in India: A Narrative Review,” Journal of Health Management, vol. 22, no. 2, pp. 157–168, Jun. 2020, doi: 10.1177/0972063420935540.
  4. G. Kampf, D. Todt, S. Pfaender, and E. Steinmann, “Persistence of coronaviruses on inanimate surfaces and their inactivation with biocidal agents,” Journal of Hospital Infection, vol. 104, no. 3, pp. 246–251, Mar. 2020, doi: 10.1016/j.jhin.2020.01.022.
  5. T. Lewis, “Infection prevention and control team. Policy on cleaning and disinfection of equipment, surfaces, environment and skin.” NorthBeccles: ECCH, 2013, [Online]. Available: https://www.ecch.org/media/1128/cleaning-and-disinfection-of-equipment-surfaces-environment-and-skin-policy-2016-1.pdf.
  6. D. J. Viscusi et al., “Impact of Three Biological Decontamination Methods on Filtering Facepiece Respirator Fit, Odor, Comfort, and Donning Ease,” Journal of Occupational and Environmental Hygiene, vol. 8, no. 7, pp. 426–436, Jul. 2011, doi: 10.1080/15459624.2011.585927.
  7. M. B. Lore, B. K. Heimbuch, T. L. Brown, J. D. Wander, and S. H. Hinrichs, “Effectiveness of Three Decontamination Treatments against Influenza Virus Applied to Filtering Facepiece Respirators,” The Annals of Occupational Hygiene, Aug. 2011, doi: 10.1093/annhyg/mer054.
  8. D. T. Weaver, et al., “UV Sterilization of Personal Protective Equipment with Idle Laboratory Biosafety Cabinets During the COVID-19 Pandemic,” Occupational and Environmental Health, preprint, Mar. 2020. doi: 10.1101/2020.03.25.20043489.
  9. A. J. Jinia et al., “Review of Sterilization Techniques for Medical and Personal Protective Equipment Contaminated With SARS-CoV-2,” IEEE Access, vol. 8, pp. 111347–111354, 2020, doi: 10.1109/ACCESS.2020.3002886.
  10. R. P. Rastogi, Richa, A. Kumar, M. B. Tyagi, and R. P. Sinha, “Molecular Mechanisms of Ultraviolet Radiation-Induced DNA Damage and Repair,” Journal of Nucleic Acids, vol. 2010, pp. 1–32, 2010, doi: 10.4061/2010/592980.
  11. J.-H. Yang, U.-I. Wu, H.-M. Tai, and W.-H. Sheng, “Effectiveness of an ultraviolet-C disinfection system for reduction of healthcare-associated pathogens,” Journal of Microbiology, Immunology and Infection, vol. 52, no. 3, pp. 487–493, Jun. 2019, doi: 10.1016/j.jmii.2017.08.017.
  12. I. Hosein, R. Madeloso, W. Nagaratnam, F. Villamaria, E. Stock, and C. Jinadatha, “Evaluation of a pulsed xenon ultraviolet light device for isolation room disinfection in a United Kingdom hospital,” American Journal of Infection Control, vol. 44, no. 9, pp. e157–e161, Sep. 2016, doi: 10.1016/j.ajic.2016.01.044.
  13. A. Guridi, E. Sevillano, I. de la Fuente, E. Mateo, E. Eraso, and G. Quindós, “Disinfectant Activity of A Portable Ultraviolet C Equipment,” IJERPH, vol. 16, no. 23, p. 4747, Nov. 2019, doi: 10.3390/ijerph16234747
  14. D. Mills, D. A. Harnish, C. Lawrence, M. Sandoval-Powers, and B. K. Heimbuch, “Ultraviolet germicidal irradiation of influenza-contaminated N95 filtering facepiece respirators,” American Journal of Infection Control, vol. 46, no. 7, pp. e49–e55, Jul. 2018, doi: 10.1016/j.ajic.2018.02.018.
  15. B. K. Heimbuch et al., “A pandemic influenza preparedness study: Use of energetic methods to decontaminate filtering facepiece respirators contaminated with H1N1 aerosols and droplets,” American Journal of Infection Control, vol. 39, no. 1, pp. e1–e9, Feb. 2011, doi: 10.1016/j.ajic.2010.07.004.
  16. W. G. Lindsley et al., “Effects of Ultraviolet Germicidal Irradiation (UVGI) on N95 Respirator Filtration Performance and Structural Integrity,” Journal of Occupational and Environmental Hygiene, vol. 12, no. 8, pp. 509–517, Aug. 2015, doi: 10.1080/15459624.2015.1018518
  17. M. S. Bergman, D. J. Viscusi, B. K. Heimbuch, J. D. Wander, A. R. Sambol, and R. E. Shaffer, “Evaluation of Multiple (3-Cycle) Decontamination Processing for Filtering Facepiece Respirators,” Journal of Engineered Fibers and Fabrics, vol. 5, no. 4, p. 155892501000500, Dec. 2010, doi: 10.1177/155892501000500405.

Full Text:
Article Info
Submitted: 2021-05-03
Published: 2021-09-30
Section: Artikel
Article Statistics: